5 User Communication
3-34 WindO/I-NV2 User’s Manual
When RXD is selected as Command Type:
Fixed Period: Data is transmitted at a fixed time interval.
Data Type: Select the data type handled by the conditional expression.
Can only be set if Satisfy the condition is selected as Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.
Device: Specifies the bit device or bit of the word device to serve as condition. You can only specify the internal
device.
Can only be set if Rising-edge or Falling-edge is selected as Trigger Type.
Click to display the Device Address Settings dialog box. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
Condition: Sets the condition formula.
Can only be set if Satisfy the condition is selected as Trigger Type.
Click to display the Trigger Condition Settings dialog box. For the conditional expressions
configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.
Period (sec): Specify the period for command execution from 1 to 3600 (seconds).
This is enabled only when Fixed Period is selected in Trigger Type.
Trigger Type: Selects the condition to be ready to receive data from the following.
Always Enabled: The MICRO/I is always ready to receive data.
While ON: Ready to receive data when the value of device is 1.
While OFF: Ready to receive data when the value of device is 0.
While satisfying the condition:
Ready to receive data while the condition is satisfied.
Data Type: Select the data type handled by the conditional expression.
Can only be set if While satisfying the condition is selected as Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.
Device:
Specifies the bit device or bit of the word device to serve as condition. You can only specify the internal
device.
Can only be set if While ON or While OFF is selected as Trigger Type.
Click to display the Device Address Settings dialog box. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
Condition: Sets the condition formula.
Can only be set if While satisfying the condition is selected as Trigger Type.
Click to display the Trigger Condition Settings dialog box. For the conditional expressions
configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.
Fixed time interval Fixed time interval Fixed time interval
Action
ExecutionExecutionExecution
Action
Always Enabled
Value of Device
1
0
Enabled Enabled Enabled
Action
1
0
Enabled EnabledEnabled
Value of Device
Action
Enabled Enabled Enabled
Condition
Satisfied
Not satisfied
Action